A 250C+
Temperature Range: 475°C to 1475°C
On-line Single Color Infrared Focusable Non-contact Pyrometers
A250C+ is a highly accurate digital two color IR Focusable pyrometer to provide high performance and low maintenance of non contact temperature measurement in demanding industrial and R&D environments. The Pyrometer measures the temperature of an object by calculating the ratio of the energies at two different wavelength bands. The ratio technique eliminates and reduces errors in temperature measurement caused by changes in Emissivity, Surface finish and energy absorbing materials such as Water Vapour etc.
The IR pyrometer parameters can be selected via the keypad on the back panel. The settings are displayed on the OLED Display. In the measuring mode, real time temperature is displayed. In Pyrometers, measuring temperature and emissivity is displayed on the television screen.
Key Features
- Wide temperature ranges from 475°C to 1475°C Focusable Optics
- Response Time 100msec.
- Emissivity 0.75 μm….1.25 μm
- Integrated OLED Display & Parameterizing Keys
- Two Color model
- Laser targeting
- Analog output options 0…20mA/ 4…20mA
- RS-485/RTU Modbus Serial interface(User Selectable)
- User friendly PC software for communication
- Green LED for pyrometer status indication and Red LED for Laser ON/OFF indication
Scope of Supply
- Pyrometer with Focusable optics, OLED Display & Parameterizing Keys
- Laser pilot light(PL)
- Analog output 0…20mA/ 4…20mA
- Digital Interface RS-485/RTU Modbus Serial Interface
- 5 mtr long connection cable with connector
- Calibration certificate, Software & Operation manual
Optional Accessories
- Mechanical & Electrical Accessories
- Extra Cable Lengths
Technical Specifications
Model | A250C+ |
Temperature Range | 475°C to 1475°C |
Spectral Range | 1.5μm/1.6 μm |
Photodetector Type | InGaAs/InGaAs |
Distance to Spot Size Ratio | 150:1 |
Emissivity Slope (ε1 / ε2) | 0.75…1.25 slope adjustable (Two color mode) |
Response Time | 100 msec adjustable upto 10 sec |
Accuracy | ± 0.5% of the measured value + 1°C |
Repeatability | 0.1% of reading in °C + 1°C |
Sighting Option | Laser Pilot Light(PL), Through The Lens (TL) & Video Module |
Analog Output | 0-20mA, 4-20mA (User selectable) |
Digital Output | RS-485/RTU Modbus Serial Interface(User Selectable) |
Operating Temp. Range | 0°C…….70°C; 0°C…..200°C (With water cooling jacket) |
Storage Temp. Range | -20°C…70°C |
Adjustable Parameters, Features via Software and Android app | Emissivity, Response Time, Clear Time (Peak Picker), Analog Output, Analog Scale (Sub range), Unit Of Temperature(°C/°F), Relay set point & hysteresis etc |
Adjustable Parameters, Features via Keypad | Emissivity, Response Time, Clear Time (Peak Picker), Analog Output, Analog Scale (Sub range), Unit Of Temperature(°C/°F), Relay set point & hysteresis, address etc. |
Relay output | One Relay output with hysteresis 60V DC / 42 AC RMS, 0.4 A |
Power Supply | 12V to 28V DC with reverse voltage protection |
Power Consumption | Max 2.5 watt |
Laser Power | <1 m watt |
Protection Class | Ip65 |
Housing | Stainless Steel |
Isolation | Power Supply, Digital Output and Analog Output are galvanically islolated against each other |
Operating Humidity | 10-95%, Non-Condensing Conditions |
Weight & Dimensions | 1200g Dia= Ø 56mm; Length=188.5mm |