EL50
Temperature Range: -20°C to 800°C
Highly Accurate Digital Pyrometer with Extended Sensor Head
El50 is an economic digital IR Pyrometer from E series with extended sensing head in 4 wire technology for non-contact temperature measurement between -20°C to 800°C.The sensor head is unaffected by electromagnetic interferences. The pyrometers are specially designed in a such way that sensor head can withstand ambient temperature upto 120°C easily.
Key Features
- Wide temperature ranges (-20°C to 800°C)
- Spectral range 8 μm…14 μm
- Power Supply (12V to 28V DC with reverse polarity protection)
- Sensor head withstands ambient temperature upto 120°C
- Inbuilt LCD Display and Keypad for parameterisation
- Fast response time within milliseconds
- Analog output 4…20mA, 0…20mA, 0…10V,
- Thermocouple type “K” or“J” (user selectable)
- USB 2.0 Digital output
- RS-232/RS-485 Serial interface card
- Relay output
- User friendly PC software for communication
Scope of Supply
- Pyrometer with LCD Display
- Keypad for parameterizing
- Extended Sensor head with 3 mtr cable
- Analog output like 4…20mA, 0…20mA, 0…10V
- Thermocouple type “K” or“J” (user selectable)
- USB2.0 Digital output, USB Cable
- Relay Output
- Calibration certificate, Software & Operation manual
Optional Accessories
- Mechanical and Electrical Accessories
- RS-232 / RS-485 interface card
- Extra Sensor Head Extension Cable Lengths
Models at a Glance
Model | EL50 |
Temperature Range (Analog sub-range adjustable) | -20°C to 800°C |
Spectral Range | 8…14 μm |
Photodetector Type | Thermopile |
Distance to Spot Size Ratio | 2:1 15:1 (To be specified while ordering) |
Emissivity (ε) | 0.1….1.2 adjustable |
Response Time | 20 msec adjustable upto 10 sec |
Accuracy | ± 1% of the measured value or 3°C whichever value is greater (The sensor head must be at constant ambient temperature for a minimum of 15 minutes) |
Repeatability | 0.3% of reading in °C + 1°C |
Sighting Option | Sighting Option Laser Pilot Light(PL) |
Analog Output | 0-20mA, 4-20mA, 0-10V, Thermocouple Type “K” or “J” (User selectable) |
Digital Output | USB 2.0 RS-232/RS-485 interface card (Optional) *At a time only one digital output possible |
Operating Temp. Range | Electronic Box upto -20°C to 70°C Sensor head upto 120°C |
Storage Temp. Range | -20°C…70°C |
Relay Output | Relay Output with hysteresis 60V DC/42V AC RMS,0.4A |
Adjustable Parameters and Features via Software | Emissivity, Response Time, Clear Time (Peak Picker), Analog Output, Sub Range, Unit Of Temperature (°C/°F), Communication mode(Comm.mode), Record feature etc. |
Adjustable Parameters and Features via Keypad | Emissivity, Setpoint, Hysteresis (Hyst), Analog Sub Range, Analog Output, Unit of temperature, Sensor address, Response Time, Clear Time (Peak Picker) etc. |
Power Supply | 12V to 28V DC with reverse polarity protection |
Power Consumption | Max 2.5 watt |
Protection Class | Ip65 |
Housing | Sensor head-Stainless Steel; Electronic Box: Zinc |
Isolation | Power supply, *Digital output and Analog output are galvanically islolated against each other * Not applicable for USB 2.0 digital output |
Operating Humidity | 10-95%, Non-Condensing Conditions |
Weight & Dimensions | 600g, 112.5mm x 82.5mm x 33mm (L x W x H) |