T3-250
Temperature Range : 250°C to 2500°C
Highly Accurate On-Line Infrared Non-Contact Pyrometer in Two-Wire Technology
T3-250 PL is specially designed IR Pyrometer of T3 Series family for non-contact temperature measurement in demanding industrial environments. The Pyrometers are highly accurate and compact by nature with stainless steel housing to provide high operational safety for harsh industrial environments. The Pyrometers are designed for high-temperature applications between 250°C….2500°C.
The parameters like Emissivity can be adjusted directly at the device. Other parameters like Analog Sub Range, Response Time, Peak Picker, Value picker etc. can be preset ex-works or adjustable via Software Infrasoft.
T3 Series is provided with TTL output. Using the USB interface Infralink and Software pyrometer can be connected to PC for parameter setting and data logging
Key Features
- Two wire technology for easy electrical connection
- Wide temperature range 250°C to 2500°C
- Spectral range 1.0 μm….1.6 μm
- Laser Light for precison targeting of the measuring object
- 10 ms response time adjustable upto 10 sec
- Output 2 wire….4-20 mA (Isolated)/TTL
- Digital TTL output & Infrasoft software
- Small spot sizes
- Emissivity can be adjusted directly at device
- Accessories for mounting and cooling options
Scope of Supply
- Pyrometer with 3 mtr. long connection cable
- Analog output 2 wire….4-20 mA
- Emissivity adjustable switch
- TTL output
- Calibration certificate, Operation manual
Optional Accessories
- Mechanical and Electrical Accessories
- USB Interface card & PC Software
- Extra cable lengths
Technical Specifications
Model | T3-250 |
Temperature Range | 250°C to 1000°C 300°C to 1300°C 350°C to 2500°C |
Spectral Range | 1.6 µm |
Photodetector Type | InGaAs |
Distance to Spot Size Ratio | 50:1 (250°C….1300°C) 100:1 (300°C….1800°C) 200:1 (350°C….2500°C |
Emissivity (ε) | 0.1….1.0 adjustable at device |
Response Time | 10 msec adjustable upto 10 sec |
Accuracy | ± 0.3% of the measured value + 1°C |
Repeatability | 0.1% of reading in °C + 1°C |
Sighting Option | Laser Pilot Light (PL) |
Analog Output | 2 wire….4-20mA, Linear Temperature Output Load : Max 500Ω at 24V DC, Max 200Ω at 18V DC |
Digital Output | TTL |
Operating Temp. Range | 0°C…….70°C 0°C…..200°C (With water cooling jacket) |
Storage Temp. Range | -20°C…70°C |
Adjustable Parameters, Features via Software and Parameterizing Keys | Emissivity, Response Time, Analog Scale (Sub Range), Unit of Temperature (°C/°F), Peak Picker, Valley Picker |
Power Supply | 24 V DC (5 to 25 V DC for Laser Targeting light (I≤30 mA) |
Power Consumption | For Laser Targeting Max 0.65 watt For Device Max 0.6 watt |
Laser Power | <1 m watt |
Protection Class | Ip65 |
Housing | Stainless Steel |
Isolation | Analog output 2 wire… 4-20mA and measurement circuit is isolated against each other (2KVAC/1mA/60sec) |
Operating Humidity | 10-95%, Non-Condensing Conditions |
Weight & Dimensions | 250gm Dia=Ø40mm; Length=113.5mm |